Skip to main content

SuperMicrobiologists

A study questions the effectiveness of the Bunsen burner

Published on 24 November 2026 6 min



For years, we have been taught that a Bunsen burner on the lab bench creates an “aseptic” zone around the flame. The famous “sterile dome”.

Well, that dome may have just collapsed…

A scientific study published in Microbiology Spectrum looked at how effective Bunsen burners are at reducing airborne contamination around the flame.

And its title already gives us a pretty good clue: “As a component of aseptic technique, Bunsen burners do not universally decrease deposition of microbe-containing particles”.

This topic is especially interesting for us at SuperMicrobiologists: our own collaborative study, carried out in 126 laboratories around the world, also produced results that were not really in favor of Bunsen burner effectiveness.

The main difference? Our experiment was based on the natural contamination present in laboratories. In this new scientific study, the researchers deliberately generated artificial, controlled contamination.

Let’s see how they did it.


We were unable to confirm your registration.
The study has just landed in your inbox… check your spam folder too! 😉

Does your Bunsen burner really protect your work?


126 laboratories put it to the test.


And the results may not be what you expect…



Bunsen burner on vs. off

The principle is very simple.

The researchers place two Petri dishes under the same conditions:

  • one 10 cm from a lit Bunsen burner

  • the other 10 cm from an unlit Bunsen burner.

Both dishes remain open for one minute. The researchers then compare the number of colony-forming units (CFU) that settle on each dish.

If this famous aseptic zone really exists, the dish next to the flame should logically collect fewer microorganisms.

But the researchers also wanted to test different contamination conditions.


Dry and wet contamination

To generate the contamination, the researchers always used the same bacterium: Gordonia rubripertincta.

The goal was to create artificial contamination that was as controlled and reproducible as possible, so the different conditions could be compared.

They then generated two types of microbial contamination in the air.

  • Dry contamination is designed to reproduce microorganisms carried by particles, for example when clothing moves or dust is disturbed.

  • Wet contamination is designed to reproduce microorganisms carried by droplets, such as those generated by a sneeze.

Importantly, the researchers did not test just one contamination level.

They took measurements at different times as the number of microorganisms in the air gradually decreased. This gave them several contamination levels, from the highest to the lowest.

This is important because the effectiveness of the Bunsen burner seems to depend on the contamination level.


So, does a Bunsen burner protect your work from contamination?

We won’t keep you waiting any longer:

Statistically, the Bunsen burner does not reduce the number of microorganisms that settle on the dishes when the researchers compare the conditions with and without a flame overall… ouch, that hurts!

But when the researchers look at the effect of the Bunsen burner according to the contamination level, things become more interesting.

With dry particles, they observed a tipping point at around 83 CFU/min.

Above this level, the Bunsen burner seems to reduce the contamination settling on the dishes. Below it, the opposite seems to happen.

Important: 83 CFU/min is not a microbiological limit to remember. It is simply the tipping point observed under the conditions of this experiment.

And 83 CFU/min is huge. If you really have this level of contamination in your lab… your main problem is probably not the Bunsen burner.

With wet particles, the result is simpler: the flame has no significant positive or negative effect across the contamination levels tested.


What do the authors conclude?

The authors conclude that the effect of the Bunsen burner on aseptic conditions depends strongly on the environmental context.

Under their experimental conditions, the benefit was limited to situations where airborne contamination with dry particles was very high (which should not normally be the case in a microbiology lab).

Outside this specific situation, the flame is either neutral or unfavorable to aseptic conditions.

The authors therefore suggest that using a Bunsen burner to reduce airborne contamination should not be considered automatically beneficial. Its usefulness depends on the actual conditions in the laboratory.

Maybe it is time to look at how we use Bunsen burners with a slightly more… critical eye!



“`