Skip to main content

SuperMicrobiologists

Cleaning and disinfection in microbiology laboratories: best practices

Published on 2 June 2026 5 min




When we signed up to become microbiologists, we did not expect that part of our job would be… cleaning the laboratory.

And yet, this “ungrateful” task is a key part of the job.

Because a dirty lab greatly increases the risk of contamination. And a contaminated lab is very likely to generate false positives.

That is why it is important to follow proper cleaning and disinfection procedures (and yes, these are two different terms that both matter), but also to regularly check the contamination level of the laboratory… using microbiological testing.

In this article, we invite you to explore this topic through discussions with several SuperMicrobiologists!


How to disinfect your micro lab?

We went looking for solutions that can make this disinfection step easier.
.

How can a microbiology laboratory become fully contaminated?

Before talking about disinfection, let’s quickly look at how a laboratory can become “contaminated”.

It always starts with a microorganism entering the lab. It can come in through microbiologists themselves (skin, clothes, shoe soles), products, positive controls… basically, microorganisms always find a way in!

If the laboratory is not cleaned properly, there is a risk that the microorganism settles somewhere and starts multiplying.

It can then become airborne through air movements inside the lab (people moving around, ventilation systems), before settling again on different surfaces and gradually “colonizing” the whole laboratory.

That is when you start finding it on the walls, above incubators and BSCs, and even on the ceiling.

And once you reach that point… getting rid of it becomes very difficult! Can you imagine standing on a stepladder to disinfect the ceiling? Neither can we… especially because we are afraid of heights.

The best approach is therefore to implement good contamination control practices and disinfect the laboratory very regularly to avoid reaching that stage.

What is good disinfection?

It always starts with proper cleaning

The basic rule is simple: you can only disinfect a clean surface.

Would you mop a floor without sweeping it first?… Well, to be honest, we already tried it once to “save time”… and it absolutely does not work!!

So the first step is cleaning, to remove dust, grease, and any layer of dirt that prevents the disinfectant from reaching the microorganisms.

For this cleaning step, unfortunately, we have not found any miracle solution… You still need a good detergent (spray, wipes, etc.) and a lot of elbow grease.

In production areas, some manufacturers use steam systems to help remove the layer of “dirt”. You scrub less aggressively, but it still remains a manual step.

Then comes the disinfection step

Once the surface is properly cleaned, you can finally disinfect it.

And yes, we know… some detergents also claim to be disinfectants. They do work. But according to several suppliers we spoke with, “2-in-1” products often perform one of the two functions less effectively… food for thought!

To disinfect, you use a… disinfectant. Choosing the right one matters because not all disinfectants have the same spectrum of activity.

The choice depends on what you want to “kill”: spores? molds? or only bacteria and yeasts?

That is why it is best to alternate products regularly in order to achieve the broadest possible spectrum of action.

This disinfection step is also still very manual. Most laboratories use wipes and spray disinfectants. However, other solutions exist to make microbiology laboratory disinfection much easier, and that is exactly what we discuss in this article.


Be careful with TACT

But be careful: for a disinfectant to be effective, you absolutely need to follow the TACT rule:

  • Time of contact: between the surface and the disinfectant

  • Action: mechanical action… you need to scrub!

  • Concentration: not the microbiologist’s concentration level, but the product concentration

  • Temperature: the disinfectant’s temperature of use


If you deviate even slightly from these parameters, you may not achieve the product’s expected performance… and therefore fail to disinfect properly.

And that is often where things go wrong.

We do not always respect the contact time (because after a long workday, we just want to finish quickly), we do not always respect the concentration (we do not use enough disinfectant… and often, we do not even realize that there is a minimum amount to use!).

We can also forget certain areas…

And that is when you realize how easily contamination can establish itself in the laboratory… and then, well… things quickly become a disaster: false positives!

As a reminder: when a product result comes back positive, the batch is blocked… and sometimes even the whole factory.

Emergency investigations are launched… and when you finally realize that the product was actually not contaminated, and that the issue came from the laboratory itself… nobody is happy about it!

Conclusion

In short, to avoid reaching that point, you ideally need:

  • A routine disinfection procedure: define how often benches, BSCs, incubators, and the rest of the laboratory should be cleaned and disinfected. Frequencies vary depending on the area.

  • An environmental monitoring program: implement a control plan to regularly check critical areas of the laboratory.

    For this, laboratories use air samplers, settle plates, contact plates (or swabs or wipes), and even ATP meters.

    But most importantly, you need to define alert limits… and take action when those limits are exceeded.

  • Un protocole de désinfection renforcé : à prévoir avant même que ça vous tombe dessus.

    Quand il y a une conta, c’est le branle-bas de combat : on augmente les zones et les fréquences de nettoyage et de désinfection.

    Et ça, on peut vous dire que dans les labos… on déteste ça.

    On a vu des labos y passer plusieurs heures par jour pour s’en débarrasser !

    Bien entendu, tout pendant que la conta est toujours présente, on renforce aussi le plan de contrôle (davantage d’analyses de surface et d’air).

    On ne revient à un fonctionnement normal que lorsque les résultats repassent sous les limites.

Un grand merci aux nombreux SuperMicrobiologistes qui ont répondu à nos questions et nous ont permis d’écrire cet article. 




Leave a Reply

Your email address will not be published. Required fields are marked *