Performing microbiological air monitoring is one thing. Knowing whether the sample is representative and what the result really means is another.

According to Philippe Armaing, there is still a lot of room for improvement in food factories when it comes to sampling methods, the choice of monitoring points and, above all, the interpretation of results.

In particular, he questions the use of passive settle plates and recommends defining criteria adapted to each area rather than automatically applying the same limits everywhere.

And when an indicator starts to drift, the number alone is no longer enough: you need to understand what is behind the increase.


Discover 7 Innovative tools to better detect

Listeria in the environment 

Air sampling: why use active air samplers?

For microbiological air monitoring, which practices do you think could still be improved in food factories?

Philippe Armaing: I still see too many air samples being collected using a plate left exposed for half an hour, three hours, one hour or even eight hours by passive sedimentation.

Nowadays, in 2026, I find that approach quite empirical. I recommend active air samplers.

With an active air sampler, you have a defined air volume, and you can also properly qualify the relevant locations that need to be monitored.

Because the locations selected for sampling are not always relevant either.

And as with other environmental sampling, if everyone does not collect samples in the same way, the results are not always truly comparable.

Why using the same limit in every area can be a problem

Once you have a result, how should you define what is acceptable and what is not?

Most of the time, with contact slides or active air samplers, sites monitor total microbial counts as well as yeasts and moulds when there is no specific microbiological concern.

But quite often, the criteria have not really been defined or qualified.

I know sites where exactly the same criteria are used in a low-risk area and in a sensitive area with positive pressure and controlled air treatment.

For me, this is something that needs to be reconsidered.


How do you recommend establishing these criteria?

I recommend starting with historical data, provided that you have enough results available.

Based on this history, you can identify the rooms where stricter requirements may be needed.

You should also take the type of air treatment into account. Is the room under positive pressure or not? Is there an air treatment system?

The criteria should therefore be qualified according to the actual conditions in each area rather than automatically applying the same value everywhere.

Linking air monitoring results to filter maintenance

When a facility has an Air Handling Unit (AHU) and an air treatment system, is there a particularly useful time to perform air sampling?

Yes. When you have an air treatment system with an Air Handling Unit, the filters need to be replaced periodically.

I quite often ask manufacturers whether they perform their air sampling just before these filter changes.

I may take a sample one month when the filters are heavily loaded. The next time, maintenance may have replaced the filters without me knowing, and suddenly I get good results.

I therefore recommend always linking air monitoring results with maintenance activities and filter changes. Otherwise, the results lose much of their value.

My recommendation is to perform the sampling before the filters are replaced, at a time when, depending on the equipment, filtration performance may potentially be lower.

Total microbial counts are increasing: do not stop at the number

What should you do when the results begin to increase significantly?

If I usually have results around 100 or 200 and, after two or three months, I start seeing 1,000 or 1,500, I need to understand which microorganisms may be responsible for the increase in my total microbial count.

The total microbial count is an indicator.

But when it increases and I cannot explain why, I need to investigate further with the laboratory.

You should not stop at simply monitoring the total microbial count.

You can perform more specific investigations using other culture media to try to identify the microorganism responsible for the trend.

Philippe also mentions metabarcoding methods, particularly for product-related investigations, which can help identify the predominant microorganism involved in a microbiological issue.



Many thanks to Philippe Armaing for sharing his experience on microbiological air monitoring and the importance of making full use of the data generated.

If you have a question, feel free to ask. We will do our best to answer it.