Skip to main content

SuperMicrobiologists

How to Prepare Microbiology Culture Media Using a Media-Preparator?

Published on 17 February 2026 9 min



This article is also available as a podcast in more than 20 languages. Click the ⚙️ Settings icon on YouTube, then choose Audio Track and Subtitles to watch it in your preferred language.


There are two main ways to sterilize culture media in a microbiology laboratory.

You can either use an autoclave, or you can use a media preparator.

And it’s this second option that caught our attention.

In this article, we went inside the Laboratoire Microsept to understand, in practical terms, how media preparators are used on a daily basis.

Guillaume Mesnard shares a clearly pragmatic perspective, built on several years of hands-on experience.


Discover the Top 3 Media Preparators

We asked the SuperMicrobiologists in a big survey.
Here’s what they said.

Laboratoire Microsept Presentation

Can you introduce your laboratory?

Microsept is a microbiological testing laboratory specialized in food analysis. We also work on water, cosmetic products, and certain products analyzed according to the European Pharmacopoeia.

The laboratory is ISO 17025 accredited for most of its activities. Cosmetics and pharmacopoeia testing are currently undergoing accreditation — which is actually one of our major ongoing projects.

In total, we perform around 200,000 analyses per year, across all matrices.

In parallel, Microsept also has a training department and a method validation service according to ISO 16140-3 for organizations such as AFNOR, MicroVal, and AOAC.


What is your role within the laboratory?

I am Head of the Validation & Expertise Department. I also manage all equipment, from purchasing to maintenance. So quite naturally, I am very involved in topics related to media preparators.


“In total, this represents between 150 and 200 liters of culture media prepared every day.”

Manufacturing Culture Media in the Microbiology Laboratory

Types of media prepared and volumes

What types of culture media do you prepare?

We prepare both broths and agar media, although broths represent the vast majority of our production. For broths, we produce all buffered peptone water, 9 mL tubes for dilutions, and specific broths for cosmetic and pharmacopoeia applications. The only exception is Half Fraser broth, due to the handling of certain supplements considered hazardous.


What volumes do you prepare on average per day?

On average, we use about 100 liters of peptone water per day. In addition, we prepare around 50 liters of other broths and between 40 and 50 liters of agar media.

In total, this represents between 150 and 200 liters of culture media prepared every day.

Equipment and Organization

How many media preparators do you have?

Today, we have seven media preparators, with capacities ranging from 10 to 50 liters. We deliberately chose different volumes to remain very flexible in our organization. This allows us to easily adjust production volumes depending on workload, peak periods, and time of day.


Do you have a dedicated room for media preparation and another for dispensing?

Yes. We have a dedicated room for preparation and autoclaving of culture media. This room is equipped with a three-phase electrical supply, which is essential for sterilization cycles, as well as a water connection for cooling the equipment.

Powder handling and weighing are performed in this room under an extraction arm, since powders are highly volatile and can be sources of contamination.

We also have three autoclaves in the same area. Once the media are prepared and sterilized, they are temporarily stored in a cold room before being used by technicians.


Is there one or several people dedicated to media production?

Yes. All laboratory technicians are trained and authorized to prepare media and use the preparators. However, one person is specifically dedicated to this task on a daily basis.

This person is permanently involved in media production, ensuring equipment monitoring, volume management, and proper organization of cycles. In practice, media production generally involves two to three people every morning, especially to start autoclave cycles.

Of course, in case of absence or workload peaks, other trained technicians can step in.


The water volume is measured using a meter installed on the water system, ensuring precise tank filling.”

Culture Media Preparation Process

Do you use ready-to-use powders or mix individual raw materials?

In the vast majority of cases, we use ready-to-use powders formulated by manufacturers, with all ingredients already standardized and homogenized. This applies to both simple and more complex media.

Mixtures made from individual raw materials are very rare and reserved for very specific method validation purposes.


What type of water do you use?

We use Type 2 water produced by our water systems. This water meets strict physicochemical criteria, continuously monitored by the machine, and its microbiological quality is verified weekly.

Even though the water is later sterilized, this quality is essential, especially for certain fragile media that cannot withstand a standard autoclave cycle.


Do you add powder to water or water to powder? Why?

In practice, we first measure the volume of water, then gradually add the powder into the water under agitation. This follows the manufacturers’ technical recommendations.

The water volume is measured using a meter installed on the water system, allowing precise tank filling.


“We maintain a backup stock of peptone water in bags, which helps us manage end-of-day needs and unexpected situations.”

Culture Media Sterilization Cycles

What sterilization cycle do you use?

Our standard cycle is 121°C for 15 minutes, with a tolerance of ±3°C. This covers about 98% of our production.

Some more sensitive media only require heating to 100°C for about ten minutes, without a full autoclave cycle. In these cases, parameters are adjusted directly on the preparator.


How long does a full cycle take?

A complete cycle lasts on average between 1 hour 45 minutes and 2 hours. This includes heating, sterilization holding time, and cooling.

The duration may vary slightly depending on the final temperature setpoint and the incoming water temperature, which is colder in winter than in summer.


Do you run cycles overnight to be ready in the morning?

No, we do not run cycles at night. Cycles are usually started in the late afternoon.

Once completed, the unit is unplugged and moved to the sample weighing room, ready for use the next morning.

We prefer to avoid overnight cycles for safety reasons, even though the equipment has many built-in protections.


At the end of the day, do you run another cycle or use pre-sterilized bags?

We maintain a backup stock of peptone water in bags to manage end-of-day needs and unexpected situations.


“A 50-liter preparator weighs around 90 kg… It’s like moving a very heavy shopping cart. If you take your time, anyone can do it.”


Discover the Top 6 Dehydrated Media Suppliers

We asked the SuperMicrobiologists in a big survey.
Here’s what they said.

Media Preparator Mobility and Ergonomics

Is it easy to move the preparator when it is full?

A 50-liter preparator weighs about 90 kg. It’s not light, but the units are designed to be easily moved.

The handles are not hot, and the wheels allow movement without excessive effort. In our setup, distances are short, around fifteen meters.

It’s like moving a very heavy shopping cart. If you take your time, anyone can do it.


“One preparator supplies two gravimetric dilutors positioned on either side of the unit.”

Connection to Dilutors and Dispensing

For dispensing peptone water, what are your preparators connected to?

In our organization, one preparator supplies two gravimetric dilutors positioned on either side of the unit.


How is the connection made?

The connection is made using stainless steel fittings screwed onto the preparator outlet. Tubing and connection kits are cleaned and sterilized after each use.

The connection is performed under sterile conditions near a Bunsen burner to minimize contamination risk.


At what temperature are media dispensed?

Media are dispensed at room temperature, between 20 and 25°C.


“Contamination may be linked to insufficiently disinfected areas … That is why strict cleaning and disinfection procedures are essential.“

Cleaning, Disinfection, and Contamination Control

How do you clean the tank between batches? Is it removable?

On small models (10 liters), the tank is removable and can be cleaned in the washing area.

On larger models, the tank is not removable. Cleaning is performed in place via a bottom drain valve.

The cleaning process includes rinsing, alcohol disinfection, then a second rinse with demineralized water.

If the unit is not restarted immediately, it is left open to allow complete drying. Sensitive areas such as outlets or lid components are treated with a sporicide, following past contamination experiences.


Do you sometimes have contaminated media?

Yes, it can happen … but fortunately it is very rare.

Contamination may be linked to insufficiently disinfected areas or parts less exposed to heat treatment. That is why strict cleaning and disinfection procedures are essential.


“The main advantage is clearly flexibility (…) The second advantage is economic.”

Advantages and Limitations of Using a Media Preparator

What are the main advantages of using a media preparator?

The main advantage is clearly flexibility. As a service laboratory, our sample volumes can vary significantly. Preparators allow us to quickly produce large quantities of peptone water without relying solely on bag stocks.

The second advantage is economic. Internal production remains less expensive than purchasing ready-to-use media, even when considering equipment investment, labor, water consumption, and maintenance.


And the limitations?

Using preparators requires real equipment management. Maintenance planning, staff training, and compliance with pressure equipment regulations are essential.

Three-phase power must be available for sterilization cycles, and water consumption (especially for cooling) must be considered.

These are constraints, but they are manageable if anticipated from the beginning.


“My only advice would be to test the equipment before purchasing.”

Advice for laboratories on how to choose the right media preparator

What advice would you give to a laboratory planning to purchase a media preparator?

My only advice would be to test the equipment before purchasing.

Using it for a few days allows you to verify whether it truly meets your laboratory’s needs and whether it is well accepted by the teams.

If testing is not possible, visiting a laboratory already equipped is an excellent alternative to better understand both the constraints and the benefits.


A big thank you to Guillaume for taking the time to explain how he uses media preparators in his microbiology laboratory.

If you have any questions about this organization, feel free to ask them in the comments.

Leave a Reply

Your email address will not be published. Required fields are marked *