How are microbiological samples taken in a cleanroom?

Published on 15 December 2025 12 min



This article is also available as a podcast in more than 20 languages. Click the ⚙️ Settings icon on YouTube, then choose Audio Track and Subtitles to watch it in your preferred language.



For ordinary people like us, it’s impossible to set foot in a pharma cleanroom… and for good reason: you need to be authorized!

To understand what really happens there, we immersed ourselves in the daily work of Pauline Hars, microbiology laboratory manager on a sterile site.

In this interview, Pauline takes us into classified areas and explains how environmental monitoring samples are carried out.

A journey to the heart of Grade A environmental control… without having to go through the dressing airlocks!

Presentation of the pharmaceutical laboratory

To start, can you introduce yourself?

I studied in a laboratory setting, in different disciplines, and that’s where I discovered microbiology.

I then specialized in quality, mainly in the food industry, which in the end has not much to do with what I do today.

I’ve now been working in microbiology for 10 years.
I first started in a contract microbiology testing laboratory, which worked for different sectors: cosmetics, environment, biocides…

Then I moved to another company, still as a contractor and still in microbiology, but this time more focused on pharmaceuticals, hospital pharmacies and biotech. I was also able to work in quality, where I held a position as quality manager.

And for almost three years now, I’ve been working in the pharmaceutical industry as a microbiology laboratory manager.


Discover the Top 4 Culture Media for EM

We asked the SuperMicrobiologists in a big survey.
Here’s what they said.




What kind of lab do you work in: sterile or non-sterile?

I work in a company that manufactures sterile medicines, more specifically sterile injectable medicines.



And in which areas do you take samples: A, B, C or D?

On our site, we have Grade C areas, Grade D areas, and Grade A areas.

Grade A is mainly inside the sterile filling isolator, which allows us to fill our medicines aseptically.
We do not have any Grade B areas.



How many environmental samples do you perform each year?

We’re talking about several tens of thousands of samples per year.


“We’re talking about several tens of thousands of samples per year.”

Culture media used for environmental monitoring

What types of media do you use?

We use only TSA agar plates. These are plates with specific neutralizers, chosen according to the disinfectant products that we use. We performed validations to check the effectiveness of the neutralizers against these disinfectants.

The plates are triple-wrapped, sterilized (gamma / radiation type), and have a lid-locking system, which secures the transport of the samples and their placement in incubation.



And do you also sometimes use other media?

Yes, we can use SDA (Sabouraud) with chloramphenicol, but that is more for investigations. For example, when we have detected molds, or when we know that an area is highly exposed to molds. In that case, we prefer this type of medium.



Do you perform growth promotion (fertility) tests on these culture media?

Yes, for each batch and each delivery of plates, we perform fertility tests.

We do them with pharmacopeia strains and with some of our endogenous strains, meaning strains that we have already found in our environment.

“The responsibility for environmental sampling always remains with the microbiology laboratory.”

Organization of sampling

Who performs the samples? Lab staff or production staff?

The responsibility for environmental sampling always remains with the microbiology laboratory. In practice, routine samples and those carried out during qualifications are performed by laboratory staff.

Some samples are delegated to production, especially Grade A samples, as well as certain in-process samples, under delegation from the laboratory.

To perform Grade A samples, you must be qualified to work under isolator. Lab staff are not qualified for this, which is why it is the production operators who perform these samples.



For what type of sampling do lab staff enter the production area?

Lab staff mainly take care of sampling in Grades C and D.



Are samples taken only during production, or also between two productions?

Environmental samples are taken during production, but also between productions. Samples are always taken in an “active” situation, even if the activity is not necessarily production, it can be cleaning or preparing equipment for the next production.



What types of samples are performed for environmental monitoring in classified areas?

We perform air sampling by sedimentation, air sampling by impaction (with a biocollector), surface sampling, and operator sampling (for example, gloves in Grade A). We also have particle counting for non-viable particles.


Discover the Top 2 Air Samplers

We asked the SuperMicrobiologists in a big survey.
Here’s what they said.

Environmental monitoring of air by active sampling

Can you explain to us the principle of impactor sampling?

Of course. We use dedicated equipment, the biocollector, in which we place our agar plate. The device is programmed and qualified to sample a certain volume of air, usually 1 m³. The air is drawn in and then impacted onto the agar through a grid. Then the plate is incubated to detect any microorganisms.



Do you use different air sampler in Grades C/D and in Grade A?

Yes, we have two types of biocollectors. We have a “mobile” type of biocollector for Grades C and D. This allows it to be moved from zone to zone, with decontamination in between. And we have different biocollectors that are “fixed” in Grade A. They are installed directly inside the isolator and handled by production staff.

The principle is the same, but because of the constraints of each zone, we cannot use the same equipment everywhere.



Do you perform only 1,000 litre samples over 10 minutes, or do you also do continuous sampling?

For air sampling by impaction, we do not perform continuous sampling.

It would be too complex to cover an entire production run with this type of sampling. So we only perform 1 m³ samples.



And during sampling, what does the operator do? Do they wait? Stay active?

The operator doesn’t just stand and watch the biocollector for 10 minutes, but they always keep an eye on it. During that time, they can label plates, prepare the next samples, start another air or surface sample, open the sedimentation plates and put them in place.

The idea is that they stay active while still monitoring that the sample is running correctly.



At what height is the air sampler placed during sampling?

In Grades C and D, the biocollectors are installed on specific stands at a defined height.

In Grade A, as the biocollectors are fixed inside the isolator, their height and position were defined through a risk assessment, so they are placed in strategic locations.



How do you manage cleaning the air sampler heads (grids) between two samples?

Between two samples, the grids are decontaminated with wipes soaked in isopropyl alcohol (IPA). We make sure to let the alcohol evaporate completely before starting the next sample. We also had to validate a specific type of wipe that does not leave residues and does not block the holes in the grid.

In addition, we carry out occasional “stronger” decontamination by autoclaving or using a sporicidal product.



What is the main difficulty with bio-impactor?

The main point of attention is really the management of the grids. You must make sure they are sufficiently decontaminated between two samples, without causing false negatives (for example due to disinfectant residue) or false positives from cross-contamination.

We also always pay attention to the sequence of samples: we start with Grade C, then Grade D (from the cleanest to the dirtiest).


“The main issue is the drying of the agar plates. They remain open for four hours… which can lead to a significant loss of water.”

Environmental sampling with sedimentation plates (90 mm)

Can you remind us of the principle of sedimentation sampling?

The principle is quite simple. You take a 90 mm TSA agar plate, open it in the area, and wait for any microorganisms present in the air to naturally settle on the surface of the agar. Then the plate is closed, incubated and the colonies are counted… if there are any!



How long do these plates stay open?

According to GMP Annex 1, they can be left open for a maximum of 4 hours.

So they stay open for the duration of the activity. If the activity lasts more than 4 hours, the plates are replaced after 4 hours, which means we are almost talking about “continuous” sampling, especially in Grade A.



Where are these sedimentation plates placed?

They are placed on specific supports, defined during the risk assessment before qualification — for example on supports already present next to tanks, or on small stainless-steel stands installed specifically for sampling.

The idea is to place them at product height and in areas representative of airflow.



Is there any particular issue to be aware of with this type of sampling?

The main issue is drying of the agar. The plates stay open for four hours in zones where airflow is very strong, which can cause significant water loss.

That’s why we validated agar fertility after 4 hours of sedimentation in the isolator. We expose the plates for 4 hours, then check that the agar is still fertile and able to support microbial growth by performing a growth promotion test.

Choosing the supplier and validating the media under our own conditions are therefore key points.


“We use a contact plate applicator. It helps standardize the pressure applied to the surface and the contact time.”

Microbiological monitoring of surfaces

For sampling with contact plates, do you use an applicator? If yes, what is it for?

Yes, we use a contact plate applicator. It helps standardize the pressure applied to the surface and the contact time.

All operators perform the sampling in the same way, which improves reproducibility. The applicators are qualified and recalibrated regularly, a bit like a biocollector.



Do you use swabs? If yes, in which cases?

Yes, we use swabs, but more for investigation sampling on difficult surfaces (joints, uneven areas, hard-to-reach spots).

We also use swabs if a torn glove is detected inside a Grade A isolator. We take a swab sample from the affected area to check if contamination has occurred.



Is there any particular issue to be aware of with this type of sampling?

For surface sampling, things are generally quite simple, but there are a few points to watch.

You must incubate the contact plates in the correct orientation (for us, agar facing down) to prevent them from detaching and falling into the lid. You need to watch out for agar defects (bubbles, lifting).

And of course, you must remember to clean the surface after sampling. We decontaminate with an IPA wipe so as not to leave culture medium on the surface, which would be a perfect support for potential contamination.


Discover the Top 4 QC Strains for Pharma

We asked the SuperMicrobiologists in a big survey.
Here’s what they said.

Other general questions about sampling

Do you perform sampling on production operators?

In Grade A, we mainly monitor operators’ gloves. At the end of a campaign, we take glove prints on 90 mm plates: the operator places all five fingers on the agar, then we close the plate and send it for incubation.


How are the plates identified? Do you write information on the plates? Does this interfere with reading?

For samples in Grades C and D, we label the plates manually with a permanent marker, directly on the bottom of the plate. We indicate the sampling point, the date, the operator, and the type of equipment used (biocollector, surface sample, etc.).

Reading is not disturbed; in case of doubt, we can always look from the top as well.

In Grade A, it’s different: plates are equipped with QR codes. Information is entered electronically after scanning, which avoids legibility issues.

In the future, we will also implement a LIMS to generate labels and retrieve all information by scanning, including for the other grades.


“The critical points are transport, incubation and any transfers between different temperatures.”

Return and incubation of samples in the lab

Once the samples have been taken, how are they brought back to the laboratory?

For Grades C and D, the operator uses a trolley where the plates are placed, takes the samples, reclips the lids and then brings the trolley back to the laboratory.

Once back in the lab, we reconcile the samples, then tape the plates together in stacks of five before incubation.

As we work with a single medium (TSA) and two incubation temperatures, these stacks also make it easier to transfer from one temperature to another without the risk of opening a plate by mistake.

For Grade A samples, the plates are placed in sterile beta-bags inside the isolator. The beta-bags are removed via the interface system and placed in airlocks. Then lab staff collect these samples, take them to the lab and put them into incubation.



At what point do you put them into incubation? How long after sampling?

We are currently validating the maximum acceptable time between sampling and incubation for the different grades.

While waiting for the end of this validation, samples are incubated as quickly as possible after they return to the laboratory.



From your experience, what are the main difficulties or sources of error in environmental sampling?

In my view, the main difficulty is ensuring that plates are not contaminated after sampling. The critical points are transport, incubation, and any transfers between different temperatures.

Contamination at this stage (for example on a Grade A sample) can have a huge impact: product under suspicion, lengthy investigations, or even batch destruction.

And in microbiology, it is always difficult to prove that a contamination comes from poor handling rather than from the environment itself. Hence the importance of not underestimating this stage.



What practical advice would you give to a microbiologist who is just starting out in a classified area?

I would tell them not to focus only on the sampling itself.

They must also pay very close attention to everything that comes afterward: handling the plates, transport, and then incubation.

We often talk about the tools (biocollectors, media, applicators…), but it’s mostly all the “around” steps that can have a huge impact on the final result.




We would like to thank Pauline for the time she gave us and for this great sharing of experience !